Employers register here
search resumes, live profiles & candidates, find online candidates, telecom wireless jobs, live jobs search engine, post telecoms jobs free
Candidates register here
submit resume, telecom wireless jobs & careers telecom contracts, technical advice, industry gurus wireless technology experts, socialize & have fun :)
Employers on-line (42)
Candidates on-line (298)

Preview Resume/CV

khurram Saleem

Resume Keywords: Job placement

Contact Information


Please log in to see contact information!

Email khurramsaleembutt@yahoo.com
khurram703@hotmail.com
Phone +92-42-7464775
Cell +966535459549
KHURRAM SALEEM BUTT
________________________________________

OBJECTIVE
To utilize my education and skills in telecommunications sector for the growth and prosperity of the organization I work with.

JOB SUMMARY

Hands on experience of Ericssons Microwave Transmission System like ML Classic/E, ML Traffic Node(TN), ML High Capacity(HC), Service on Microwave(SOM), Marconi Digital Radio System EC/S(MDRS),Ericssons 2G/2.5G RBS like 2206, 2107, 2207, 2108, 2111, 2308, 2309, 2116 and 2216, Nokia Flexi hopper and Metro hopper Microwave Equipment, Nokia 2/2.5G Ultrasite/Metrosite BTS, Huaweis Microwave Transmission System like 610,620, Huaweis 2G/2.5G BTS like 312, 3012 and NECs Microwave Transmission System like Pasolink, NEO Series and PNMS which includes Installation Supervision, Installation, Commissioning, Integration and Troubleshooting.

EXPERIENCE

MW BackOffice Consultant (Huawei Technologies Saudi Arabia (NOC)) Nov 2009To Date

Installation, Commissioning, Integration and Troubleshooting of Ericssons Microwave Transmission System which includes ML Classic/E, ML Traffic Node(TN), ML High Capacity(HC), Service on Microwave(SOM)
DCN Planning
Microwave Support provided to Customer, Project Implementation, Front Office(F)) , Field Maintenance(FM) teams regarding ML E, ML TN, ML HC and SOM

Services Engineer 1(Ericsson Pakistan) Nov 2006Feb 2009

Installation, Configuration, Integration and Troubleshooting of Ericssons MiniLink Classic, Traffic Node (TN) and High Capacity (HC) microwave PDH and SDH links as TRANSMISSION ENGINEER.
Installation, configuration and troubleshooting of CROSS POLARIZATION INTERFERENCE CANCELLER (XPIC) links using MMU2F modems.
Hands on experience of HOT STAND, SPACE DIVERSITY, FREQUENCY DIVERSITY IMPLEMENTED links.
SOFTWARE, HARDWARE and CAPACITY Upgrades
Installation and configuration of AMM 2p, 2pB, 6p B/C/D and 20p Indoor Magazines.
Hands on experience of MMU2, MMU2B, MMU2C, MMU2E and MMU2F modems.
Good understanding of SMU, NPU2, NPU3, NPU 8*2 and NPU1B.
Installation and configuration of LTU 16/1, LTU3 12/1, LTU 155e, LTU 155e/o.
Installation and Commissioning of TMR 9302 outdoor transmission cabinet
Installation and Commissioning of ETU
Cross Connection of E1s in the Backplane
SNCP Creation
Line side configuration in MLHC for DCN communication
Radio side configuration in MLHC for DCN communication
Software Up gradation (R2,R3)
Link Up gradation ( 16E1, 32E1, STM-1 and XPIC )
NPU Up gradation ( NPU 8*2 to NPU1B ) on live nodes
Cutovers of Microwave Links
Generation and Installation of License Key Files(LKF)
Preparing of Commissioning and PAT Documents
Links ready for Provisional Acceptance Test(PAT)
DCN configuration on almost 2000 MLTNs( 2p,6p and 20p) and MLHC at Hub sites and End sites either on site or remotely from SOM
Supervision of Subcontractors

Hands on experience of Central Microwave Management tool (SOM R8 SP3) in NOC

SOM SUSE Linux 9.3 Based Server Installation and Configuration
SOM XP Based Client Installation and Configuration
Core Installation
Plug-In Installation
License Manager Installation
Fault Management(FM)
Configuration Management(CM)
Performance Management(PM)
Security Management
Remote Backup/Restore Management
Inventory Management
System Administration and Troubleshooting
Patch Installation
Auto Discovery
Remote Software Upgrades in MLTN and MLHC
Addition, modification and deletion of nodes and Subnetworks
All types of DCN configuration in Traffic Node and High Cap e.g. Dedicated E1 or Channelized E1 with traffic pass-through
Traffic routing

Installation and Commissioning of MDRS S and Marconi EC/ Marconi Long Haul Microwave Equipment

1+1 Hot Standby Configuration
Space Diversity
1+1 Frequency Diversity
N+M Line Configuration
Change of all grounding KITs installed on wave guides
Humidity measurements in the Waveguide & valuate if the humidity exceeds the maximum value
Measurement of return loss of the WG to determine damages of the WG
Pressure test of each WG, locate leakages
Terminate & re-terminations of WG connectors
Fade margin test for each channel

Hands on experience of Ericssons DXX nodes e.g. Basic 3, Basic 6, 6345/6350 switch node

Installation, Commissioning and Troubleshooting of Ericssons 2/2.5G RBSs

The 2/2.5G RBSs are 2106, 2206, 2107, 2207, 2108, 2111, 2308, 2309, 2116 and 2216
Material Called Off before moving to site
Mobilization of ASPs Implementation Team
Site Visit to check that Material Delivery is Safe, Proper and in accordance with SMR and BOQ
Installation Monitoring of ASPs according to Ericsson Standards
Final Installation Inspection with QASIS Team Members
RED LINED SIDS submission back to ASPs
Commissioning and Integration of Sites
Final Verification of Sites that no extra material is on site and sent back to Warehouse
Quality check visits as per Ericsson Standards
Sites made ready for Provisional Acceptance Test(PAT) according to Ericsson Standards
Handing over of Sites to MS with QASIS TEAM members
Expansions of RBSs
Swapping of Huawei BTS with Ericsson RBSs
Alarms verification and troubleshooting of DURUS and OPTIMA RECTIFIER
Supervision of Subcontractors
Rollout Management

Installation and Commissioning of OPTIMA and DURUS rectifier

Microwave/Transmission 0&M Team Leader (Huawei Technologies Pakistan) Nov 2005Nov2006

Installation, Integration, Commissioning and troubleshooting of NEC PDH and SDH MW transmission which includes Pasolink and NEO Series
End to End Leased line Media Testing
Installation, Integration, Commissioning and troubleshooting of Huaweis Short Haul Microwave System RTN 600 Series including 610, 620 nodes
Hands on experience on Huawei MUX(OSN 1500,2500,3000,3500)
Installation ,configuration , commissioning & integration of the Huawei (BTS 3012, BTS3012AE)
Swapping of Nortel Equipment with Huawei Equipment
Managing Space, Power and Tower(SPT) requirements
I report to Power team about power issues like Gen set Failure, Low fuel, No ATS panel, No wapda etc
Hands on experience of NEC PNMS in HUAWEIS OMC-R( addition, modification, deletion and troubleshooting of NEC nodes )
Perform daily operations at all telecommunication systems within MW
Handle and follow up all escalated problems concerning MW
Send/receive/follows up with trouble reports sent to the Contractor/Buyer
Offer expert knowledge concerning parameters and configuration of MW
Offer expert knowledge concerning processes and procedures applicable for system operation
Perform stand-alone test of MW and surrounding equipment
Perform replacement of faulty equipment on order from Field Support Center Contractor
Recognize and correct faults caused of bad workmanship
Perform preventive maintenance of MW equipment installed on site
Provide knowledge transfer to Customer personnel according to the following topics
Fault management
Configuration management
Performance management
Field maintenance
Emergency handling

BSS or Field Supervisor (Komconsults Pvt Ltd Pakistan) Nov 2003Oct2005

TRANSMISSION EQUIPMENT

Installation, Commissioning and Troubleshooting of Ericssons MiniLink Classic, Traffic Node (TN) and High Capacity (HC) microwave PDH and SDH links
.
Installation and configuration of AMM 2p, 6p and 20p Indoor Magazines.
Hands on experience of MMU2, MMU2B, MMU2C modems.
Good understanding of SMU, NPU2, NPU 8*2.
Installation and configuration of LTU 16/1, LTU 155e, LTU 155e/o.
Installation and Configuration of Radios(RAU1,RAU1N, RAU2, RAU2N)
Installation and alignment of Microwave dishes(.6m,1.2m,1.8m)
Radio Cable installation and Preparation of RJ 6 cable connectors
Grounding of Radio cable
Hands on experience of HOT STAND, SPACE DIVERSITY, FREQUENCY DIVERSITY IMPLEMENTED links.
E1 cross connections
Software Up gradation (R2,R3)
Capacity Up gradation (4 E1, 8 E1, 16 E1)
Preparing of Commissioning and PAT Documents
Links ready for Provisional Acceptance Test(PAT)
Conducting LOS surveys using Balloon and Flash Test
Supervision of Technicians and Riggers

Installation, integration and Commissioning of MDRS S and Marconi EC/ Marconi Long Haul Microwave Equipment

1+1 Hot Standby Configuration
Space Diversity
1+1 Frequency Diversity
N+M Line Configuration
Change of all grounding KITs installed on wave guides
Humidity measurements in the Waveguide & valuate if the humidity exceeds the maximum value
Measurement of return loss of the WG to determine damages of the WG
Pressure test of each WG, locate leakages
Terminate & re-terminations of WG connectors
Fade margin test for each channel




BASE STATION SUBSYSTEM (BSS) EQUIPMENT

Installation, Commissioning and Troubleshooting of Ericssons 2G RBS

The 2G RBSs are 2106, 2206, 2107, 2207
Installation of GSM Antennas as per FDD
Installation of Andrew and Katherine Feeder Cables as per FDD
Preparation of Andrew and Katherine Feeder Cable Connectors
Installation of RBSs as per Floor Diagram
Installation of TMAs
Power Test of RBSs
External Alarm Patching, Definition and Troubleshooting
IDB creation and installation
Quality check visits as per Ericsson Standards
Sites made ready for Provisional Acceptance Test(PAT) according to Ericsson Standards
Expansions of RBSs

NOKIA TRANSMISSION EQUIPMENT

Installation, commissioning and integration of Nokia Flexi hopper and Metro hopper (M/W) 4E1, 8E1, 16E1 PDH and STM links
Installation and commissioning of RRI cards in Outdoor and Indoor BTS.

NOKIA BASE STATION SUBSYSTEM (BSS) EQUIPMENT

Installation, commissioning and integration of Nokia Ultra site BTS (outdoor and indoor).
Installation, commissioning and integration of Nokia Metrosite BTS (outdoor and indoor).
Installation of Katherine GSM antennas.
Power Test of Radios (TRX) of BTS.
Integration of Nokia Ultra site BTS using microwave and leased line Media.
Installation & commissioning of Nokia FIU19 at DTEs for leased lines connectivity.
Troubleshoot of external alarms of sites.
Preparation of sites for PAT (Provisional Acceptance) & FAT (Final Acceptance).
Quality check visits as per Nokia standards.
Expansion of sites in Lahore South Region.
Installation and commissioning of Mast Head Amplifiers (MHA).

NOKIA (Power One) & SALTEC RECTIFIER

Installation of Power One rectifier cabinet.
Commissioning & maintenance of Power One rectifier.
Installation & commissioning of Saltec rectifier at DTEs.
Troubles shoot of alarms of Power One & Saltec rectifier.
Installation of Power One and North Star battery backup system.
Eltek Rectifier
Site surveys using Flash and Balloon Test.




Trainings from Ericsson

GSM RBS 2216/2216 Installation, Verification and Maintenance
WCDMA system overview
Minilink TN, HC Operation and Maintenance

Qualification

M.Sc Degree in Electronics & Telecommunications
Testing Tools Used

VSWR, DTF AND RETURN LOSS measurements using SITE MASTER.
E1 TESTING which includes ES, SES, UAS, DM using BERT METER.
Radio Coverage Measurement and DT using TEMS.
TEMS Link Planner

Softwares Used

MINILINK SERVICE MANAGER (MSM)
LOCAL CRAFT TERMINAL (LCT)
MINILINK CRAFT( 1.0,1.1 and 2.3)
LOCAL MAINTENANCE TERMINAL(LMT)
OPERATION AND MAINTENANCE TERMINAL (OMT)
BULLET PROOF FILE TRANSFER PROTOCOL (BPFTP)
WEB LCT
MAP INFO
AUTOCAD

Computer Skills

MS office
Operating System Windows (All Versions)

References
Provided on request
No submited work experiences
No submited educations
No submited languages
Job Category: Transmission/Microwave/SDH Jobs
Job Type: Any Job Type
Job Status: Flexible
Desired Salary: $5000 a month
Desired Location: Not Specified
Willing to Relocate: Yes